Welcome to DBE Journal, formerly Outreach Impact.
NEWS & EVENTS       GET CERTIFIED       FIND SUBCONTRACTS
Find Subcontract Opportunities


Outreach Coordinator

Lynda Whetzel



Project Estimator

Chris Hulse, Commercial Manager / chulse@azuria.com



Contact Information

580 Goddard Ave
Chesterfield, MO 63005



Telephone

(540) 955-9671 ext. 109



Fax

(540) 955-2872



Insituform Technologies
is seeking qualified MBEs, WBEs, WSSC/SLBE, MDOT MBE-WBEs


Project Name

SANITARY SEWER REPLACEMENT/REHABILITATION (SSR) TASK NO. 111 FOR ROCK CREEK BASIN



Bid/Contract #

PROJECT NO. CRCICKLRMH7173A21



Awarding Agency

WASHINGTON SUBURBAN SANITARY COMMISSION



Project Location

The project is located in Derwood area, Montgomery County County, MD



Bid Date

05/08/2025 at 02:00



Project Details

Insituform Technologies highly encourages qualified SLBE/WBE/MBE firms to submit pricing.

Description of Project: The Work to be performed under this Task Order consists of the repair, rehabilitation, or replacement of 22,774 LF (4.31 miles) of defective sewer mains, 3,432 LF (0.65 miles) of defective sewer laterals, and 126 manholes located in the Rock Creek Basin, Prince George’s County, Maryland.

Please use the link below to access the bid documents.

https://drive.google.com/drive/folders/1qO2uewVVTioxSY9-w5IO739QqHy9KRLD?usp=sharing

Project Details: We are Seeking quotes for Replace Sanitary Sewer Main Pipe 8”at 0’-12’ Depth, Replace Sanitary Sewer Main Pipe 8” at 12’-20’ Depth, Replace Sewer House Connection 4” by Excavation; 0’-12’ Depth, Replace Sewer House Connection 4” by Excavation; 12’-20’ Depth, 8” Diameter pipe Sewer Main External Point Repair at 0’-12’ Depth, 15” Diameter pipe Sewer Main External Point Repair at 0’-12’ Depth, 8” Diameter pipe Sewer Main External Point Repair at 12’-20’ Depth, Furnish and Install Manhole over Existing Sewer, Type 1 or 2, 4’ inside dia. with F&C, Furnish and Install Inside Mainline Drop Connection, Removal of Existing Manhole and replace with Standard Manhole 4’ inside dia. with F&C, < 10’ Depth, Removal of Existing Manhole & Replace w/ standard MH 4', >10' Depth, Locate Existing Buried Manhole - In Paved Area, Locate Existing Buried Manhole - In Unpaved Area, Reset/Set Manhole Frame and Cover, Furnish New 24”-36” Manhole Frame and Cover, Manhole Grade Ring Adjustment, Manhole Riser Adjustment, Chemical Grouting Sealing, Chimney Seal, Repair/Modify Manhole Bench, Cementitious Reconstruction for 4’ Inside Diameter Manhole, Spray-on Epoxy Liner for 4’ Inside Diameter Manhole, 8” Diameter Sewer - Heavy Cleaning with Video Inspection, 10” Diameter Sewer - Heavy Cleaning with Video Inspection, 8” Diameter Sewer Main Pipe Bursting, Reconnection of Non-renewed Laterals, Montgomery County Roads Restoration, Bituminous Concrete Overlay, 1” Thickness, Milling, 1” Thickness, 4” Concrete Sidewalk, 6” Concrete Driveway, Curb and Gutter Replacement, Street - Trees, Seed Grassing, Sod Grassing, Pruning (Trimming), Tree Removal (greater than 4” DBH), Grind Stump and Surface Roots (greater than 6” at grade), Gravel- Trench Backfill, Borrow Material- Trench Backfill (Replacement of unsuitable material), GAB: Graded Aggregate Base, Set-up Sewage Bypass Pumping System (above 5 MGD to 10 MGD; payable for sewers up to and including 30”), Operate Sewage Bypass Pumping System (above 5 MGD to 10 MGD; payable for sewers up to and including 30”)



We are an equal opportunity employer and intend to negotiate with registered/qualified WSSC-SLBE and MBE/WBE for project participation and provide quick pay agreements. For Technical Questions contact Chris Hulse chulse@azuria.com

For assistance in obtaining bonds, lines of credit and/or insurance for the project or any of the above information, please contact lwhetzel@amlinereast.com or call 540-955-9671.




Copyright © 2025, DBE GoodFaith, Inc. All rights reserved.