Welcome to DBE Journal, formerly Outreach Impact.
NEWS & EVENTS       GET CERTIFIED       FIND SUBCONTRACTS
Find Subcontract Opportunities


Outreach Coordinator

Lynda Whetzel



Project Estimator

Chris Hulse, Commercial Manager / chulse@azuria.com, Randall Sourbeer, Estimator / rsourbeer@azuria.com



Contact Information

580 Goddard Ave
Chesterfield, MO 63005



Telephone

(540) 955-9671



Fax

(000) 000-0000



Insituform Technologies
is seeking qualified DBEs, MBEs, WBEs, WSSC/SLBE, MDOT MBE-WBEs


Project Name

SANITARY SEWER REPLACEMENT/REHABILITATION (SSR) TASK NO. 112 FOR BROAD CREEK BASIN



Bid/Contract #

PROJECT NO. CRCILRMH7298A22



Awarding Agency

WASHINGTON SUBURBAN SANITARY COMMISSION



Project Location

Broad Creek Basin, Prince George’s County, MD



Bid Date

05/08/2025 at 02:00



Project Details

Insituform Technologies highly encourages qualified SLBE/WBE/MBE firms to submit pricing.

Description of Project: The Work to be performed under this Task Order consists of the repair, rehabilitation, or replacement of 20,014 LF (3.79 miles) of defective sewer mains, 3,605 LF (0.68 miles) of defective sewer laterals, and 95 manholes located in the Broad Creek Basin, Prince George’s County, Maryland.

Please note that all pricing must conform to the WSSC pricing sheet included. If you intend to participate, please sign and return the attached WSSC subcontracting and Supplier Certification participation form.

Please use the link below to access the bid documents.

https://drive.google.com/drive/folders/1F9RN7iBU3QCP9eeohRVdcEgacW5foncN?usp=sharing

Project Details: We are Seeking quotes for Replace Sanitary Sewer Main Pipe 8”at 0’-12’ Depth, Replace Sanitary Sewer Main Pipe 8” at 12’-20’ Depth, Replace Sewer House Connection 4” by Excavation; 0’-12’ Depth, Replace Sewer House Connection 4” by Excavation; 12’-20’ Depth, 8” Diameter pipe Sewer Main External Point Repair at 12’-20’ Depth, Furnish and Install 4” or 6” Cleanout in excess of 10’ depth of cut, Removal of Existing Manhole and replace with Standard Manhole 4’ inside dia. with F&C, < 10’ Depth, Removal of Lamphole and replace with Standard Manhole 4’ inside dia. with F&C up to 10’ depth, Locate Existing Buried Manhole - In Unpaved Area, Reset/Set Manhole Frame and Cover, Furnish New 24”-36” Manhole Frame and Cover, Manhole Grade Ring Adjustment, Chimney Seal, Cementitious Reconstruction for 4’ Inside Diameter Manhole, Cementitious Reconstruction for 5’ Inside Diameter Manhole, 8” Diameter Sewer - Heavy Cleaning with Video Inspection, 8” Diameter Sewer Main Pipe Bursting, Incorporated Cities Roads Restoration, 4” Concrete Sidewalk, 6” Concrete Driveway, Curb and Gutter Replacement, Street - Trees, Pruning (Trimming), Tree Removal (greater than 4” DBH), Grind Stump and Surface Roots (greater than 6” at grade), Gravel- Trench Backfill , Borrow Material- Trench Backfill (Replacement of unsuitable material), GAB: Graded Aggregate Base.



We are an equal opportunity employer and intend to negotiate with registered/qualified WSSC-SLBE and MBE/WBE for project participation and provide quick pay agreements. For Technical Questions contact Chris Hulse chulse@azuria.com

For assistance in obtaining bonds, lines of credit and/or insurance for the project or any of the above information, please contact lwhetzel@amlinereast.com or call 540-955-9671.




Copyright © 2025, DBE GoodFaith, Inc. All rights reserved.